The new generation XG-PON power Meter is used on measure B-PON, E-PON and G-PON and next generation high speed 10G PON such as XG-PON and 10G-EPON networks, It also combine the function of pass/fail for network trouble shooting Model 
				 STC-PON106AP 
				 Wavelength 
				 1270nm 
				 1577nm 
				 1310nm 
				 1490nm 
				 1550nm 
				 Pass Zone(nm) 
				 1260~1280 
				 1560~1580 
				 1300~1320 
				 1480~1500 
				 1540~1560 
				 Isolation (dB) 
				 >30@1310 
				 >40@1270 
				 >40@1270 
				 >40@1270 
				 >40@1270 
				 Isolation(dB) 
				 >40@1490 
				 >40@1310 
				 >40@1550 
				 >40@1310 
				 >40@1310 
				 Isolation(dB) 
				 >40@1550 
				 >40@1490 
				 >40@1490 
				 >30@1550 
				 >30@1490 
				 Isolation(dB) 
				 >40@1577 
				 >30@1550 
				 >40@1577 
				 >40@1577 
				 >30@1577 
				 Measurement Range 
				 -40~+10 
				 -40~+10 
				 -40~+10 
				 -40~+10 
				 -40~+20 
				 Measurement Accuracy 
				 Connatural uncertainty(dB) 
				 ±0.5 
				 Linearity(dB) 
				 ±0.1 
				 Passing through insertion Loss(dB) 
				 <1.5 
				 General Information 
				 Detector Type 
				 InGaAs 
				 Optical Connector 
				 SC/APC FC/APC(UPC optional) 
				 Fiber Type 
				 9/125um 
				 Display 
				 LCD:128*64 
				 Measurement Unit 
				 dB/dBm/xW 
				 Resolution (dB) 
				 0.01 
				 Power Supply 
				 3  AA1.5V battery 
				 Operation Temperature(℃) 
				 -10~60 
				 Storage temperature(℃) 
				 -25~70 
				   Dimension(mm) 
				 200 X90 X50 
				   Weight(g) 
				 285 
				
Features
 Can identify B-PON, E-PON,G-PON mixed with new generation 10G-EPON or XG-PON
 Supports tests in B-PON, E-PON, G-PON and XG-PON/10G-EPON networks
 Through-mode capability for simultaneous measurement and display of voice, data and RF video signals on fiber at 1490/1550/1577nm downstream and 1270nm/1310nm upstream
 Convenience for threshold setting, which can set the threshold on the tester 
 USB communication port enables data transfer to a PC
 Offers up to 10 different threshold sets in total
 10 minutes Auto-off function can be activated or deactivated with keypad operation.
Specification