Model |
STC-PTT107 |
|
Judgment Mode |
||
Total Mode |
8 |
|
Output Power Value Measurement |
||
Calibration Wavelength |
1310nm |
1490nm |
Pass Zone(nm) |
1260~1360 |
1470~1505 |
Isolation (dB) |
>40@1490 |
>30@1310 |
Isolation(dB) |
>40@1550 |
>40@1559 |
Measurement Range(dBm) |
-40~+10 |
-40~+10 |
Measurement Accuracy |
||
Connatural uncertainty(dB) |
±0.5 |
|
Linearity(dB) |
±0.1 |
|
Passing through insertion Loss(dB) |
<1.5 |
|
Detector Type |
InGaAs |
|
Optical Connector |
FC/SC Interchangeable |
|
Fiber Type |
9/125um |
|
VFL Mode |
||
Output power |
1mW or 10mW |
|
General Information |
||
Display |
TFT |
|
Measurement Unit |
dB/dBm/xW |
|
Resolution (dB) |
0.01 |
|
Power Supply |
3 AA1.5V battery |
|
Operation Temperature(℃) |
-10~60 |
|
Storage temperature(℃) |
-25~70 |
|
Dimension(mm) |
200 X90 X50 |
|
Weight(g) |
285 |